Benefits
- No wear - Stainless steel construction with high resistance to corrosion, pressure and temperature
- Useable in hazardous areas - SIL2 certified according to IEC 61508 Edition 2
- Space-saving installation - Integrated reduction of nominal diameter for economic installation
- Redundant data management - Exchange of electronics without loss of calibration and configuration data
- Advanced energy management - Gross and net heat calculation
Details
Nominal size flanged version
|
DN15 to DN300 (½” to 12”)
|
---|---|
Nominal size sandwich version
|
DN15 to DN100 (½” to 4”)
|
Process values
|
Volume flow, mass flow, corrected volume flow, density, temperature, pressure, heat energy
|
Accuracy
|
Steam and gases: +/- 1% Liquids: +/- 0.75% |
Current output
|
4 - 20 mA HART (loop powered)
|
Digital output
|
Pulse (max. 1000 Hz), frequency, status, limit switch
|
Communication
|
HART 7, Profibus PA and Foundation Fieldbus in preparation
|
Pressure rating
|
PN 10 – 100; Class 150 - 600
|
Medium temperature
|
-40 … 240 °C (-40 … 464 °F)
|
Material sensor
|
Stainless steel 1.4404 (316L), Hastelloy C22 on request
|
Transmitter enclosure
|
Die-cast aluminium
|
Enclosure rating
|
IP66 / 67 (NEMA 6)
|
Connection
|
EN 1092-1; ASME B16.5 Wafer design (centering rings included) |
Remote transmitter
|
Connection cable up to 50m (164 ft), remote version in preparation
|
Temperature sensor
|
Standard integrated temperature sensor
|
Pressure sensor
|
Optional integrated pressure sensor with or without isolation valve
|
Display and keypad
|
High-resolution graphical display and 4 operating keys (alternative use magnet pen)
|
Ex approvals
|
ATEX II2 G Ex ia - QPS IS Class I Div.1 - IECEx II2 G Ex ia ATEX II2 G Ex d - QPS XP Class I Div.1 - IECEx II2 G Ex d ATEX II3 G Ex nA - QPS NI Class I Div. 2 - IECEx II3 G Ex nA ATEX II2 D Ex tb - QPS DIP Class II, III Div. 1 - IECEx II2 D Ex tb |
Safety integration level (SIL)
|
SIL2 according to IEC 61508
|
Application examples
|
chemical, power, and oil and gas installations
|