Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
EKG M & E SDN BHD
EKG M & E SDN BHD 201201033712 (1018200-D)
Waktu
Pejabat
Isnin - Jumaat 9:00 AM - 5:30 PM
Sabtu 9:00 AM - 1:00 PM
Ahad Closed
We′re closed on Public Holiday
Open Closed
SSM
PENGUNJUNG

27-Mar-2026

Ventilation Performance Check | Mechanical & Volumetric Audit by EKG

In a high-rise commercial environment, "running" is not the same as "performing." A Ventilation Performance Check is a deep mechanical diagnostic that compares your system's current output against its original engineering design. In Kuala Lumpur’s 2026 climate, most systems lose 20% to 30% of their performance within five years due to belt slippage, motor wear, and "blinded" cooling coils.

As part of a Ventilation Systems Audit, EKG performs these checks to move your building from "functional" to "optimized," focusing on air volume, pressure, and motor efficiency.


1. The Three Indicators of System Decay

We audit the "Mechanical Resistance" that forces your fans to work harder for less air:

  • The "Choke" Effect: Clogged filters or scaled cooling coils act like a wall. We measure the Pressure Drop (Delta P) across these components. If it exceeds 250 Pa, your fan is wasting energy fighting an obstruction.

  • Volumetric Slippage: We measure the actual Cubic Feet per Minute (CFM) at the fan discharge. If the motor is at 100% speed but only delivering 80% air, you have a mechanical failure in the impeller or a massive duct leak.

  • Thermal Bypass: We check if the air is actually being cooled and dehumidified. In KL, if your ventilation "performs" but the humidity remains above 70%, your cooling coils or ERVs are failing.


2. The EKG "Actual-vs-Design" Protocol

Our engineers use precision metrology to verify the "Health" of your AHUs and Extract Fans:

  • Fan Curve Verification: We measure the Total Static Pressure and RPM. By plotting this on the fan's original "Manufacture Curve," we can see if your fan is operating in an inefficient "surge" zone.

  • Pitot-Tube Duct Traverse: This is the "Gold Standard" for accuracy. We measure the air velocity inside the main riser to calculate the exact volume of air moving through the building.

  • Vibration & Thermal Signature: We use laser tachometers and IR cameras to find "Hot Bearings" and misaligned pulleys. We identify the Fan Mechanical Signature before it leads to a catastrophic motor failure.

  • VFD Frequency Mapping: We audit your Variable Frequency Drive (VFD). We ensure your "Standard Operation" isn't pinned at 50Hz (Full Speed) when the building is only half-occupied.


3. The Energy Impact: The Cube Law

A "Poorly Performing" system is an energy thief. When a fan fights against resistance, its efficiency plummets while its power draw (kW) spikes.

  • Friction Restoration: By identifying and removing "Airflow Chokes" (dirty coils, seized dampers), we lower the total resistance.

  • The Logic: Because of the Cube Law, a 20 percent reduction in fan speed results in a nearly 50 percent reduction in power consumption. A Performance Check provides the "Mechanical Data" to safely lower your VFD frequencies.


4. Ventilation Performance Matrix

Component Healthy Performance At-Risk (Needs Overhaul)
Main Supply Fan pm 10 of Design CFM > 25 Deviation (Choked/Leaky)
Cooling Coil $\Delta P$ 100 to 150  Pa > 250  Pa (Deep Clean Needed)
Motor Amperage Within Nameplate FLA Over-Amperage (Friction/Load)
Air Velocity 2.0 to 3.5 m/s > 5.0 m/s (High Friction/Noise)
Vibration < 2.5 mm/s > 4.5 mm/s (Bearing Failure)

5. Why Trust EKG for Performance Checks?

  • Holistic Repair Path: We don't just hand you a report. We are experts in Mechanical Fan Overhauls, offering chemical degreasing, bearing replacement, and laser alignment to physically restore performance.

  • VFD ROI Projection: We calculate exactly how much money you are "exhausting" into the street, providing a clear Ringgit-based ROI for any recommended repairs.

  • 2026 Technical Standards: We ensure your building meets the latest Malaysian Energy Commission (ST) and DOSH (JKKP) efficiency mandates.

  • Transparency: You receive a "Traffic Light" executive summary, allowing you to prioritize maintenance budgets where they will have the biggest impact on energy and comfort.

Hantar mesej anda ke EKG M & E SDN BHD
Terima kasih untuk pertanyaan anda!
Perkhidmatan pelanggan kami akan menghubungi anda tidak lama lagi.
Nama Anda *
Nama Syarikat Anda
Emel Anda *
Nombor Telefon Anda *
Tajuk *
Mesej *
Captcha *
Pejabat Utama

EKG M & E SDN BHD 201201033712 (1018200-D)
27-2 & 27-3, Jalan Kuchai Maju, Kuchai Entrepreneur¡¯s Park, Off Jalan Kuchai Lama, 58200 Kuala Lumpur, Malaysia.

Tel:

Emel:
Laman Web: https://www.eakon.com.my
Laman Web: https://eakon.newpages.com.my/
Laman Web: https://eakon.onesync.my/

Melayari Melalui : Laman Utama - Klasifikasi - Syarikat - Tempat - Tag - Produk - Berita Baru dan Promosi - Jawatan Kosong - Laman Web Mudah Alih - Google - Keputusan SEO

NEWPAGES

Seni Jaya Logo
Brochure
Download
Our PackageContact Us