Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
EKG M & E SDN BHD
EKG M & E SDN BHD 201201033712 (1018200-D)
Waktu
Pejabat
Isnin - Jumaat 9:00 AM - 5:30 PM
Sabtu 9:00 AM - 1:00 PM
Ahad Closed
We′re closed on Public Holiday
Open Closed
SSM
PENGUNJUNG

26-Mar-2026

Negative Air Machine Servicing | 2026 Engineering & Compliance Standards

In 2026, Negative Air Machine (NAM) Servicing in Malaysia is a high-stakes technical requirement governed by DOSH ICOP IAQ 2026 and CIDB CIS 28 safety mandates. Because NAMs are used to create pressure differentials ( -5 Pa minimum) to contain hazardous dust, mold, or pathogens during renovation, their failure constitutes a major legal liability. Under the Energy Efficiency and Conservation Act (EECA) 2024, these units must also be audited for motor efficiency and power consumption.

At EKG M&E, we apply 34 years of engineering depth to provide "Zero-Bypass" servicing that restores your containment integrity while maintaining your building's mandatory Energy Intensity Label.


1. 2026 Compliance: Pressure & Aerosol Integrity

Under the DOSH 2026 framework, a Negative Air Machine is only "compliant" if it is physically validated on-site. Simply changing filters is no longer enough for an audit trail:

  • In-Situ PAO Leak Testing: We perform Polyalphaolefin (PAO) aerosol scans on the HEPA filter face and housing gaskets. In 2026, any leak exceeding 0.01% is an automatic failure for hazardous containment sites.

  • Pressure Differential Validation: We calibrate the integrated digital manometers to ensure the unit can maintain a steady -5 Pa to -10 Pa relative to the "Clean Zone."

  • Airflow Traverse (CFM): We use thermal anemometers to verify that the unit is moving its rated volume (e.g., 2,000 CFM) to meet the mandatory 6 to 12 Air Changes per Hour (ACH).


2. EECA 2024: VFD Tuning & The Cube Law

The EECA 2024 (enforced Jan 2025) targets NAMs as high-load equipment. Running a NAM at full speed when the containment zone is empty is now a regulatory violation for "Energy Waste."

  • Variable Frequency Drive (VFD) Optimization: We recalibrate the VFD parameters to maintain the target pressure using the least amount of electricity.

  • The Cube Law Advantage: Following the Cube Law, if the VFD reduces the fan speed by just 20% (e.g., during night-time "Maintain" mode), the power consumption drops by nearly 50%. This ensures your site meets its Minimum Energy Performance Standard (MEPS) for 2026.


3. Media Management & Scheduled Waste (SW 410)

In 2026, the disposal of used NAM filters is a strictly regulated process overseen by the Department of Environment (DOE).

  • SW 410 (Pathogenic Waste): Spent HEPA filters from mold remediation or clinical sites are classified as Scheduled Waste (SW 410).

  • e-SWIS Documentation: EKG manages the secure bagging, labeling, and legal e-Consignment through the e-SWIS portal, providing you with the "Second Copy" manifest required for your environmental and CIDB audits.

  • Decontamination: Every NAM serviced at our facility undergoes a UV-C and antimicrobial fogging cycle to ensure no biological "Carry-Over" between job sites.


4. Mechanical Health: FFT Vibration Analysis

NAMs are portable and frequently moved, making them prone to mechanical fatigue and "impeller shift."

  • Blower Health Audit: We perform Fast Fourier Transform (FFT) vibration analysis on the motor and fan assembly. This detects early signs of bearing wear or housing cracks that could lead to a catastrophic containment failure.

  • Resonance Protection: We identify any harmonic peaks caused by the portable housing and program the VFD to "skip" those frequencies. This prevents "Media Flutter" and ensures the unit runs at its quietest, most stable "Sweet Spot."


Why Trust EKG M&E for NAM Servicing?

  • 34 Years of Engineering Depth: Malaysia's specialists in high-integrity air containment and pressure-controlled environments.

  • Audit-Ready Reporting: We provide the PAO Integrity Certificates, VFD-Energy ROI Reports, and DOE e-SWIS Manifests for every service.

  • On-Site or Workshop Service: We offer rapid response across the Klang Valley for emergency filter replacements and integrity testing.

Hantar mesej anda ke EKG M & E SDN BHD
Terima kasih untuk pertanyaan anda!
Perkhidmatan pelanggan kami akan menghubungi anda tidak lama lagi.
Nama Anda *
Nama Syarikat Anda
Emel Anda *
Nombor Telefon Anda *
Tajuk *
Mesej *
Captcha *
Pejabat Utama

EKG M & E SDN BHD 201201033712 (1018200-D)
27-2 & 27-3, Jalan Kuchai Maju, Kuchai Entrepreneur¡¯s Park, Off Jalan Kuchai Lama, 58200 Kuala Lumpur, Malaysia.

Tel:

Emel:
Laman Web: https://www.eakon.com.my
Laman Web: https://eakon.newpages.com.my/
Laman Web: https://eakon.onesync.my/

Melayari Melalui : Laman Utama - Klasifikasi - Syarikat - Tempat - Tag - Produk - Berita Baru dan Promosi - Jawatan Kosong - Laman Web Mudah Alih - Google - Keputusan SEO

NEWPAGES

Seni Jaya Logo
Brochure
Download
Our PackageContact Us