Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
EKG M & E SDN BHD
EKG M & E SDN BHD 201201033712 (1018200-D)
Waktu
Pejabat
Isnin - Jumaat 9:00 AM - 5:30 PM
Sabtu 9:00 AM - 1:00 PM
Ahad Closed
We′re closed on Public Holiday
Open Closed
SSM
PENGUNJUNG

24-Mar-2026

Smoke Control Panel Integration by EKG M&E Sdn Bhd

In the high-rise landscape of KL and PJ, the Smoke Control Panel (SCP) is the "brain" of the building’s life-safety system. It serves as the critical interface between the Fire Alarm System and the mechanical ventilation hardware. EKG M&E Sdn Bhd specializes in Smoke Control Panel Integration, ensuring that fans, dampers, and pressurized zones respond instantly and accurately during a fire emergency, in full compliance with BOMBA and UBBL standards.


The Engineering Logic of Integration

Integration is not just about wiring; it is about "Sequence of Operations." When a smoke detector is triggered, the SCP must execute a complex series of commands:

  • Zoned Response Logic:

    The system identifies exactly where the smoke is. It opens the Motorized Smoke Dampers in the fire zone while keeping dampers in other zones closed to prevent smoke migration.

  • HVAC Shutdown & Fire Mode Override:

    To prevent the cooling system from spreading smoke, the SCP sends a signal to shut down all general office AC units. Simultaneously, it triggers the Variable Frequency Drives (VFDs) of the Smoke Spill fans to bypass all energy-saving limits and run at 100% capacity.

  • Pressurization Synchronization:

    The panel activates the Stairwell and Lift Lobby Pressurization fans. It monitors the pressure levels to ensure they stay at the mandatory 50 Pa (Stairwells) and 15 Pa (Lobbies), providing a smoke-free escape route.

  • Make-Up Air Interlock:

    For every cubic meter of smoke exhausted, the SCP triggers motorized fresh air louvers or supply fans at a low level. This prevents "Negative Pressure," which would suction exit doors shut and trap occupants.


Critical Hardware Interface

We ensure seamless communication between diverse M&E components:

Component Interface Role Engineering Goal
Main Fire Alarm Panel (MFAP) The "Trigger" Sends the initial 24V or volt-free signal to the SCP.
BMS / SCADA The "Monitor" Provides real-time status of fan speeds and damper positions.
Fireman’s Switch The "Master Override" Located at the Fire Command Centre for manual control by BOMBA.
Field Actuators The "Muscles" High-torque motors that physically move dampers and vents.

Why Choose EKG M&E Sdn Bhd?

  • HVAC & Clean Air Specialist: We perform Differential Pressure Mapping and Hot Smoke Visualization Tests to validate that the panel logic actually clears the smoke as designed. We don't just "test the lights"; we test the airflow.

  • Fail-Safe Reliability: We utilize fire-rated cabling and redundant power supplies (Genset backed) to ensure the control signal isn't lost if the fire damages the building's main power grid.

  • Klang Valley Strategic Support: Based in Kuala Lumpur, we provide professional SCP programming, annual sensor calibration, and BOMBA-readiness audits for commercial and industrial hubs across the Klang Valley.

Hantar mesej anda ke EKG M & E SDN BHD
Terima kasih untuk pertanyaan anda!
Perkhidmatan pelanggan kami akan menghubungi anda tidak lama lagi.
Nama Anda *
Nama Syarikat Anda
Emel Anda *
Nombor Telefon Anda *
Tajuk *
Mesej *
Captcha *
Pejabat Utama

EKG M & E SDN BHD 201201033712 (1018200-D)
27-2 & 27-3, Jalan Kuchai Maju, Kuchai Entrepreneur¡¯s Park, Off Jalan Kuchai Lama, 58200 Kuala Lumpur, Malaysia.

Tel:

Emel:
Laman Web: https://www.eakon.com.my
Laman Web: https://eakon.newpages.com.my/
Laman Web: https://eakon.onesync.my/

Melayari Melalui : Laman Utama - Klasifikasi - Syarikat - Tempat - Tag - Produk - Berita Baru dan Promosi - Jawatan Kosong - Laman Web Mudah Alih - Google - Keputusan SEO

NEWPAGES

Seni Jaya Logo
Brochure
Download
Our PackageContact Us