Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
EKG M & E SDN BHD
EKG M & E SDN BHD 201201033712 (1018200-D)
Waktu
Pejabat
Isnin - Jumaat 9:00 AM - 5:30 PM
Sabtu 9:00 AM - 1:00 PM
Ahad Closed
We′re closed on Public Holiday
Open Closed
SSM
PENGUNJUNG

24-Mar-2026

A Direct Expansion (DX) Precision Cooling System is the standard for small-to-medium data centers and server rooms in Kuala Lumpur and Selangor. Unlike chilled water systems that rely on a central building plant, a DX system is self-contained, using a refrigeration cycle (compressor, evaporator, and condenser) to remove heat directly from the IT environment.

EKG M&E Sdn Bhd specializes in the design, installation, and 24/7 maintenance of DX precision units, ensuring your critical hardware stays within the ASHRAE TC 9.9 thermal envelope.


1. How a DX Precision System Works

In a DX system, the "evaporator coil" is located inside the computer room air conditioning (CRAC) unit.

  • Heat Capture: Warm return air from the server racks is pulled over the evaporator coil.

  • Phase Change: The liquid refrigerant inside the coil absorbs the heat and boils into a gas.

  • Heat Rejection: The gaseous refrigerant is pumped to an outdoor air-cooled condenser, where the heat is released into the Malaysian atmosphere, and the refrigerant is condensed back into a liquid to repeat the cycle.


2. DX vs. Comfort Air Conditioning

For a server room in KL, a standard "split-unit" AC is a risky choice. A DX Precision system offers three critical advantages:

Feature Standard Split-Unit AC DX Precision (CRAC)
Sensible Heat Ratio (SHR) ~0.60 to 0.70 (Wastes energy removing moisture) 0.90 to 1.00 (Designed for 100% dry IT heat)
Duty Cycle Intermittent (8–10 hours/day) Continuous (24/7/365)
Airflow Volume Low (Designed for human comfort) High (Designed to penetrate deep into server racks)
Precision $\pm 3^{\circ}\text$ variance $\pm 1^{\circ}\text$ and $\pm 5\%$ Relative Humidity

3. VFD Integration and Inverter Technology

Legacy DX systems used fixed-speed compressors that "cycled" on and off, causing temperature swings and high electrical wear. We utilize Variable Frequency Drives (VFDs) and Inverter Compressors to modernize these systems:

  • Load Matching: The VFD allows the compressor to modulate its speed. If your server load drops at night, the system slows down rather than turning off, maintaining a perfectly flat temperature line.

  • Energy Savings: Inverter-driven DX units can reduce energy consumption by 25% to 35% compared to fixed-speed units.

  • Soft Starts: VFDs eliminate the high "inrush current" during startup, protecting your building's electrical breakers and the compressor motor.


4. Critical Maintenance for DX Systems

Because DX systems rely on pressurized refrigerant, proactive maintenance is mandatory in Malaysia's high-ambient heat:

  • Refrigerant Charge Monitoring: We check for leaks and ensure the "Sub-cooling" and "Super-heat" levels are perfect. An undercharged system will run 24/7 but fail to cool the racks.

  • Condenser Coil Cleaning: KL’s urban dust can quickly coat outdoor condenser fins. We perform quarterly chemical cleaning to ensure the system can reject heat efficiently during 33°C afternoons.

  • Vibration Analysis: We perform FFT Spectrum Analysis on the internal blower fans. We detect bearing wear early, preventing a catastrophic "fan-fail" that would cause a server room thermal trip.


Why Choose EKG M&E Sdn Bhd?

  • Turnkey MEP Capability: We handle the Electrical Sub-panels, the Ref-piping, and the BMS integration for a complete cooling solution.

  • 24/7 Emergency Support: Based in Kuala Lumpur, our technicians are on-call to handle refrigerant leaks or compressor failures before they impact your uptime.

  • 34-Year History: We have designed stable DX environments for medical labs, telecommunication hubs, and financial server rooms across Malaysia.

Hantar mesej anda ke EKG M & E SDN BHD
Terima kasih untuk pertanyaan anda!
Perkhidmatan pelanggan kami akan menghubungi anda tidak lama lagi.
Nama Anda *
Nama Syarikat Anda
Emel Anda *
Nombor Telefon Anda *
Tajuk *
Mesej *
Captcha *
Pejabat Utama

EKG M & E SDN BHD 201201033712 (1018200-D)
27-2 & 27-3, Jalan Kuchai Maju, Kuchai Entrepreneur¡¯s Park, Off Jalan Kuchai Lama, 58200 Kuala Lumpur, Malaysia.

Tel:

Emel:
Laman Web: https://www.eakon.com.my
Laman Web: https://eakon.newpages.com.my/
Laman Web: https://eakon.onesync.my/

Melayari Melalui : Laman Utama - Klasifikasi - Syarikat - Tempat - Tag - Produk - Berita Baru dan Promosi - Jawatan Kosong - Laman Web Mudah Alih - Google - Keputusan SEO

NEWPAGES

Seni Jaya Logo
Brochure
Download
Our PackageContact Us