Brand : SYMC
Model : BC580LN Series
Product Descriptions
BC580LN indicator is designed with a patented structure to simplify the installation work load but the IP protection reach IP65. The BC580LN enclosure uses 304 stainless steel material and is special suitable for healthy concerned food/beverage industry or anti-corro-sive chemical industry. With supporting attachments, the BC580LN terminal can be mounted on the wall or column supports.
Product Features
- Patented structure design, simple installation
- IP68 protection for water or dust and anti-corrosive.
- New generation of embedded high speed processor, strong on anti-interference
- Optimized digital filter and quick following technology
- 4~20mA/0~10V analog out available
- Over/under limit alarming
- Embedded Setpoint comparison function
| Model | P.N | Description |
| BC580LN1 | 22000338 | Harsh enclosure, Red LED, RS232/RS485, 220VAC |
| BC580LN2 | 22000339 | Harsh enclosure, Red LED, 4–20mA, 220VAC |
| BC580LN3 | 22000340 | Harsh enclosure, Red LED, Profibus DP, 220VAC |
| BC580LN1 (DC) | 22000341 | Harsh enclosure, Red LED, RS232/RS485, 24VDC |
| BC580LN2 (DC) | 22000342 | Harsh enclosure, Red LED, 4–20mA, 24VDC |
| BC580LN3 (DC) | 22000343 | Harsh enclosure, Red LED, Profibus DP, 24VDC |
Technical Specifications
| Enclosure | Harsh enclosure. Material: SS304, IP65 | ||
| Run Mode | 2-speed material transfer mode, Setpoint comparison, Over/under, Check weigh, Reduction weigh, Peak force measurement, Gross/net fill | ||
| Signal Range | –20 mV ~ +20 mV | Increments | 1, 2, 5 × 10ⁿ (n = –3 ~ 1) |
| Max. Sensitivity | 0.5 µV/d | Max. Resolution | 1/100,000 |
| FS Drift | 3 ppm/°C | Linearity | 0.003% FS |
| AD Refresh Rate | 50–200 Hz | Cells Load | Six (6) × 350 Ω load cells |
| Display | 7-digit, 1'' (25 mm) height segment LED | ||
| Keypad | 5 tactile-feel keys; polyester overlay | ||
| Discrete I/O | 2 Inputs; 3 Relay Outputs (220 VAC @ 5 A) | ||
| USART | COM1: RS232; COM2: RS485 | ||
| Serial Protocol | MODBUS-RTU, Command output, Continuous Output, Print | ||
| Option | 4–20 mA / 0–10 V, Profibus DP | ||
| Power Supply | 100–240 VAC, 60 mA / 24 VDC, 150 mA | ||
| Operating Temperature | 10°C ~ +40°C; Relative humidity: 10%–90%, non-condensing | ||