code: M1440
Battery powered datalogger for external CO2 probe up to 10 000ppm or 50 000ppm and inputs for connecting up to three temperature and/or humidity probes.
Multilogger can be installed permanently to Ethernet network or work as portable device.
Included is traceable calibration certificate in accordance with EN ISO/IEC17025.
The Multilogger is a battery operated datalogger capable of measuring and recording sensor and electrical values through its inputs.
Datalogger can be connected to Ethernet. Then measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
INCLUDED IN DELIVERY:
CO2 EXTERNAL PROBES ARE NOT INCLUDED IN DELIVERY AND THE PROBE 10.000PPM OR 50.000PPM WITH A CABLE LENGTH 1, 2 OR 4 METERS MUST BE ORDERED
| TEMPERATURE SENSOR - external probe Pt1000 | |
| Measuring range | -200 to +600 °C | 
| Accuracy | ±0.2 °C (-200 to +100 °C); <br>±0.2 % from reading from +100 to +600 °C | 
| Resolution | 0.1 °C | 
| TEMPERATURE+HUMIDITY SENSOR - external probe T+RH DIGI | |
| Measuring range | according to the connected probe Digi/M | 
| Accuracy | according to the connected probe Digi/M | 
| Resolution | 0.1 °C | 
| DEW POINT | |
| Measuring range | according to the connected probe Digi/M | 
| Accuracy | according to the connected probe Digi/M | 
| Resolution | 0.1 °C | 
| CO2 SENSOR 10.000ppm (OPTIONALLY) | |
| Measuring range | 0 to 10.000 ppm | 
| Accuracy | 100 ppm + 5% of the measured value at 23 °C a 1 013 hPa | 
| CO2 SENSOR 50.000ppm (OPTIONALLY) | |
| Measuring range | 0 to 50.000ppm | 
| Accuracy | < ±(1,5 % from full scale +2% from the measured value) | 
| Resolution | 1 ppm | 
| External probe cable length CO2 | 1, 2 or 4 meters | 
| GENERAL TECHNICAL DATA | |
| Operating temperature | -10 to +60 °C | 
| Channels | 3x external temperature probe or connectable temperature+humidity probe, 1x external CO<sub>2</sub> sensor | 
| Counted values | dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy | 
| Memory | 1 000 000 values (noncyclic record), 600 000 values (cyclic record) | 
| Recording interval | 1s to 24 hours | 
| Display and alarm refresh | each 10 s | 
| Recording mode | noncyclic - data logging stops after filling the memory<br>cyclic - after filling memory oldest data is overwritten by new | 
| Available temperature units | degrees Celsius, degrees Fahrenheit | 
| Communication interface | Ethernet, USB, RS232 | 
| Ethernet communication protocols | WWW, SNMPv1, XML, DATALINK | 
| Alarm protocols | |
| Power | AC adapter 230Vac/5Vdc (neccessary for Ethernet interface) | 
| Battery life | 3 - 4 weeks | 
| Protection class | IP20 | 
| Dimensions (without connectors) | 178 x 95 x 37mm, without attached cables | 
| Weight (including batteries) | approx. 380 g | 
| Warranty | 3 years | 









 
            
            


 BR                                21913
BR                                21913                             VN                                8755
VN                                8755                             US                                7533
US                                7533                             MY                                6061
MY                                6061                             AR                                2785
AR                                2785                             MX                                1757
MX                                1757                             GB                                1461
GB                                1461                             CN                                1322
CN                                1322                             
         
        
 
        