Please login to use this feature.
You can use this feature to add the product to your favourite list.
Close
You have removed this product from your favourite list.
Close
Please login to use this feature.
You can use this feature to add the company to your favourites list.
Close
This company has been removed from your favourite list.
Close
Please login to use this feature.
You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
You have removed this product from your favourite list.
Close
Daily Login Reward
Congratulations!
You¡¯ve earned your daily login reward for today!
5 NP PointHere are the reward you¡¯ve earned!
Check your Daily Login Rewards
Be sure to come back everyday for more rewards!
Thanks!
Scan and Whatsapp Me
Note: Some mobile phone default QR scanners cannot scan to open the WhatsApp App directly.
Cancel
Waktu
Pejabat
Isnin - Jumaat 9:00 AM - 5:00 AM
Sabtu - Ahad Closed
We′re closed on
Public Holiday
Get the latest
VG Instruments (SEA) Sdn Bhd
App for Android
Open
Closed
Selangor,Kuala Lumpur (KL),Kepong - Pembekal Level and pressure measurement and point level detection in mixing processes
11-Dec-2018
Reaction vessel with agitator
Level and pressure measurement and point level detection in mixing processes
Process data
Measuring task
Level measurement and point level detection
Measuring range up to
3 m
Medium
Pharmaceutical raw materials and mixed products
Process temperature
-20 … +120 °C
Process pressure
-1 … +10 bar
Special challenges
Internal tank fixtures
Application
The key component in the manufacture of pharmaceutical products is the reactor. Different raw materials are mixed with solvents and made to react by applying heat and pressure. During this process, the pressure, temperature and consistency of the medium are changing constantly. A stirrer ensures homogeneous mixing of the product, and can also cause an agitated surface and heavy foaming. To ensure a reliable process, the liquid level in the reaction vessel must be reliably and continuously monitored.
Your benefit
Reliable
Certified materials in compliance with FDA and EC 1935/2004
Cost effective
Three instruments, four measured values: Pressure, level, temperature and point level
User friendly
Low installation expenditure
Recommended products
VEGAPULS 64
Non-contact level measurement with Radar
- Reliable level measurement, independent of process conditions such as temperature, changing product density and condensate
- Focusing of the sensor allows accurate measurement despite stirrers
Measuring range - Distance
VEGABAR 83
Pressure transmitter for monitoring pressure
- Unaffected by internal fixtures such as agitators or heating coils
- Unaffected by foaming
Measuring range - Distance
Measuring range - Pressure
VEGASWING 61
Vibrating level switch for point level detection
- Reliable measurement, independent of process parameters
- Adaptable to any medium through special coatings, e.g. glass and polymer
Measuring range - Distance
Hantar mesej anda ke VG Instruments (SEA) Sdn Bhd