- Low measurement sequence - Emissivity adjustable between 0.1 and 1.0
- Automatic shutdown - Switchable laser sighting aid
- Measured value display selectable between °C and °F
- Different exhibition settings - Battery operation
- Compact and robust design
Resolution ≤ 1000 °C: 0.1 °C > 1000 °C: 1 °C
Accuracy -50 … 0 ºC: ± 3 ºC > 0º C: ± 1.5 % or ± 2.0 the larger value counts
Measuring function Type K Measuring range -50 … 850 ºC
Resolution ≤ 1000 °C: 0.1 °C > 1000 °C: 1 °C
Accuracy ± 1.5 % or ± 1.5 °C the larger value counts
Measuring function
Air temperature
Measuring range -20 … 60 ºC
Resolution 0.1 °C Accuracy 0 … 40 ºC: ± 1.0 ºC
Other: ± 2 °C
Measuring function Humidity
Measuring range 0 … 100 % r.H.
Resolution 1 % Accuracy 35 … 75 % r.H.: ± 3.0 % r.H. Other: ± 5 % r.H.
Measuring function Dew point
Measuring range -20 … 60 ºC
Resolution 0.1 °C Accuracy 25 ºC, 40 … 80 % r.H.: ± 1.5 ºC
Wet bulb temp.
Measuring range -20 … 60ºC
Resolution 0.1 °C
Accuracy 25 °C: ± 1.5 °C
Emissivity adjustable between 0.1 and 1.0
Optical resolution 13 : 1
Response time ≤ 500 ms
Spectral sensitivity 8 … 14 um
Laser ≤ 1 mW, 630 … 670 nm, class 2 laser
Automatic shutdown after one minute
Operating conditions 0 … 50 ºC / ≤ 95% r.H.
Storage conditions -20 … 70 ºC / ≤ 80 % r.H.
Power supply 9 V battery Weight ca. 130 g
1 x Thermocouple Type-K
1 x 9 V block battery
1 x Carrying bag
1 x User manual