Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
Utsource Holding Company Limited
Utsource Holding Company Limited 58474938-000-06-24-A
Onesync AI SSM
Business Nature:

Manufacturer Supplier Wholesaler

Causes of Sporadic Air Circuit Breaker Tripping - Utsource Holding Company Limited

Causes of Sporadic Air Circuit Breaker Tripping

09-Sep-2025

As the most commonly used short-circuit protection device in today's power distribution systems and electronic control circuits, air circuit breakers, in various models and specifications, dominate the market. Their advantages over traditional short-circuit protection devices like fuses are well known to many of us, so I won't elaborate here. However, in actual use, air circuit breakers may trip sporadically in some situations. Because there's no obvious fault in the system, and these intermittent faults often leave us, as electricians, feeling overwhelmed. So, what are some possible causes of these circuit breaker malfunctions in daily work? Today, we'll briefly analyze the possible causes.

First, incorrect circuit breaker model selection.
This situation often occurs when using the DZ47 series miniature air circuit breaker. A typical example is when some companies use a C series civilian version of the circuit breaker instead of a D series power version when controlling power loads. As a result, when the power load experiences conditions not found in residential systems (such as sudden load changes or frequent short-duration starts), the C-series circuit breaker will trip. Therefore, when selecting an air circuit breaker, be sure to ensure the model is compatible with the operating environment!

Second, Improper Circuit Breaker Specifications
This situation often arises when the circuit breaker selection specialist fails to fully consider the actual load conditions. For example, in a motor control circuit, they focus only on the motor's rated current while ignoring objective factors such as the motor's starting conditions and starting current. As a result, the selected circuit breaker capacity may be insufficient for the motor's operation (the circuit breaker capacity is only slightly greater than the load current), leading to sporadic circuit breaker tripping. This situation is most common on the main circuit breaker responsible for the line.

Third, Hidden Faults in the System
Common fault types in this situation include: loose connections, soft insulation breakdown, transient fluctuations in grid quality, and overloads. Because these faults are often subtle and deceptive, they are often overlooked.

 In addition to the three common fault causes mentioned above, other factors that may cause air circuit breakers to trip sporadically include: failure to replace the corresponding circuit breaker in a timely manner to accommodate load expansion (often overlooked); high-power electromagnetic interference (for example, a high-power inverter without a filter reactor); improperly set circuit breaker setting values; and aging circuit breakers due to long-term use.
Main Office

Utsource Holding Company Limited 58474938-000-06-24-A
1111 Sullivan St Irvine, CA 92614 U.S.A.

Tel:

Email:
Website: https://www.utsource.us
Website: https://utsource.newpages.com.my/
Website: https://utsource.onesync.my/

Other Office

Mexico
Eje Central Lazaro Cardenas No.13 Piso 1005 Col.centro C.P.06050 Mexico£¬D.F.

Tel:
Tel:
Email:

Germany
Germany.

Tel:
Tel:
Email:

Hong Kong
FLAT/RM 22 5/F WAH LUEN CENTRE 15-21 WONG CHUK YEUNG STREET FOTAN NT HONG KONG.

Tel:
Email:

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

  • BR 16917
  • US 5678
  • CN 2689
  • AR 2051
  • SG 1392
  • EC 1053
  • BD 901
  • AU 876
People Online
Seni Jaya Logo
Brochure
Download
Our PackageContact Us