AREA OF APPLICATION
• Basement & Diaphragm Wall | • Reinforced Concrete Wall & Slab |
• Concrete Joint | • Lift Pits |
• Subway & Tunnels | • Dams |
• Sewerage Structure | • Water Tank |
• Manhole & Wet Shaft | • Brickwork |
• Rock and Soil Stabilization | • Other Specialized Applications |
FEATURES & ADVANTAGES
• Low viscosity | • Penetration into cracks <200 microns |
• Excellent bond strength | • Provides water resistant barrier |
• Good chemical resistance & Non-corrosive | • Unaffected by salts or contaminants in water |
• Halogens & CFC-Free | • Injectable with single or twin line machine |
UNIT | PART A | PART B | TEST METHOD | |
Appearance | - | Whitish Liquid | Dark Brown Liquid | - |
Viscosity (at 25 °C) | mPa.s | ~115 | ~128 | KS A 0531 |
Specific Gravity (at 25 °C) | - | ~1.04 | ~1.21 | KS M ISO 2811-1 |
Flash Point | °C | >200 | >200 | DIN 53213 |
Mixing Ratio (A:B) | litre | 1 | 1 | - |
Tensile Strength | N/mm2 | ~60 | KS M 3015:2003 | |
Tensile Shear Adhesive Strength | N/mm2 | ~6 | KS M 3705:2015 | |
Compressive Strength | N/mm2 | >100 | KS M 3015:2003 | |
Flexural Strength | N/mm2 | ~78 | KS M 3015:2003 |
REACTION DATA
Without Water | With Water | |||
900F | 900S | 900F | 900S | |
Cream Time | - | - | ~1min | ~1min 30sec |
Curing Time | ~1hours | ~4hours | ~20mins | ~30mins |
Pot life (at 25 °C) | ~5mins | ~30mins | - | - |
depending on site condition.
INJECTION PROCESS
Mix homogeneously Part A and Part B in 1:1 ratio by volume in a suitable clean and dry container. Inject mixed resin with single-line injection machine. Ensure resin is injected within the pot life of the material after mixing.
Twin-line Injection Process (for NCL SW-900F & 900S):
Fill containers of 1:1 ratio twin-line injection machine with Part A and Part B separately. Inject material through the injection gun equipped with static mixer into the structure to be sealed.
FINAL PRODUCT
PACKAGING
Contents | Weight | |
Part A : Resin | 19 kg | |
Part B : Hardener | 21 kg |
STORAGE & HANDLING
WASTE DISPOSAL
HEALTH & SAFETY
- Ingestion: Do not induce vomiting. Treat symptomatically and get medical attention immediately.
- Inhalation: Remove from exposure. If there is any difficulty in breathing, get medical attention immediately.
- Skin Contact: Remove contaminated clothing. Immediately flush affected area thoroughly with mild soap and water.
- Eye Contact: Immediately flood eyes with plenty of water for a minimum of 15 minutes holding the eyes open.
OTHER INFORMATION
For this and other reasons, NCL Chemical & Equipment Sdn Bhd do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the material. However, we have no control over the method of application and the amount of care taken when using this product and therefore the liability of NCL Chemical & Equipment Sdn Bhd is limited to the quality of the delivered material.