Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
EKG M & E SDN BHD
EKG M & E SDN BHD 201201033712 (1018200-D)
Business
Hours
Monday - Friday 9:00 AM - 5:30 PM
Saturday 9:00 AM - 1:00 PM
Sunday Closed
We′re closed on Public Holiday
Open Closed
SSM
VISITORS

30-Mar-2026

Constant Pressure VSD Control Logic | Precision Pressurization by EKG

In high-performance commercial and industrial buildings, Constant Pressure VSD Control is the standard for maintaining a stable "Static Pressure" (Ps) within your ductwork or piping. Unlike traditional systems that vary pressure based on the fan's "Peak Curve," this logic uses real-time feedback from Pressure Transducers to modulate motor speed. In 2026, this is the core strategy for preventing "Duct Whistling," avoiding air starvation in remote zones, and maximizing energy savings through the Cube Law.

As part of a Ventilation Systems Audit, EKG provides the PID loop tuning and sensor calibration required to turn your AHUs into self-regulating pressure assets.


1. The Physics of the "Closed-Loop" Logic

Constant pressure control operates on a continuous feedback loop between the VSD and the building's physical environment:

  • The Process Variable (PV): A pressure transducer—typically located 2/3 down the duct run—measures the actual static pressure.

  • The Setpoint (SP): We program a target pressure (e.g., 250 Pa). This is the minimum pressure required to ensure the furthest VAV (Variable Air Volume) box can deliver its design airflow.

  • The Error Signal: The VSD’s internal PID Controller calculates the difference between the PV and the SP.

  • The Response: If a zone damper closes and the pressure rises, the VSD instantly slows the fan to return to the setpoint. If more zones open and pressure drops, the VSD ramps up the speed.


2. The EKG "Zero-Oscillation" PID Tuning Protocol

A VSD is only as good as its programming. Poorly tuned "Constant Pressure" logic leads to "Hunting"—where the fan speed fluctuates rapidly, causing mechanical wear and occupant discomfort.

  • Proportional Gain (P): We adjust how "aggressively" the VSD reacts to a pressure change. Too high, and the system overshoots; too low, and it becomes sluggish.

  • Integral Time (I): This "removes the offset," ensuring the fan eventually hits the exact setpoint rather than just getting close. We calibrate the integral to match the "Air Lag" of your specific duct length.

  • Derivative Action (D): Usually disabled for ventilation, but used in high-speed industrial processes to "predict" pressure spikes and dampen the motor’s reaction.

  • The "Sleep Mode" Threshold: We program a minimum frequency (e.g., 20Hz). If all zone dampers close and pressure remains high, the VSD enters "Sleep Mode" to save energy and protect the motor from overheating at low RPMs.


3. The Energy & Operational Impact: The Cube Law

Constant pressure logic is the most reliable way to exploit the Fan Affinity Laws for 24/7 savings.

  • Eliminating "Over-Pressurization": Without a VSD, as zone dampers close, the duct pressure "rides the fan curve" upward, wasting massive amounts of energy to fight against closed dampers.

  • The Logic: Constant pressure logic ensures the fan only does the work required to maintain the minimum safe pressure.

Because of the Cube Law, if the VSD can maintain your target pressure by running at 40Hz instead of 50Hz during partial-load hours, your energy consumption drops by nearly 50%.


4. Constant Pressure Control Health Matrix

Component Maintenance Standard Failure Symptom
Pressure Transducer Calibrated to pm 1  Pa Fan Stays at 100% or "Hunts"
Sensing Tube Clear of Dust & Kinks Erratic Speed Fluctuations
PID Parameters Tuned for Duct "Lag" Mechanical Vibration / Noisy Ducts
Minimum Speed Set to ge 20 \ Hz Motor Overheating / Bearing Wear
VSD Display No "Ground Fault" Alarms System Trips during Pressure Spikes

5. Why Trust EKG for Control Logic?

  • Mechanical Restoration Path: We don't just tune the electronics; we are experts in Mechanical Fan Overhauls, ensuring your dampers and guide vanes are functioning so the VSD logic has a "clean" environment to control.

  • VFD-Energy ROI Projection: We provide a data-logged report showing the Ringgit savings achieved by switching from "Fixed Speed" to "Constant Pressure" logic.

  • BOMBA Fire-Linkage: We ensure that in the event of a fire, the "Constant Pressure" logic is bypassed, and the VSD ramps to 100% Manual Override for smoke spill.

  • 2026 Technical Standards: We use digital manometers and force gauges calibrated to the latest MS1525 and ASHRAE efficiency guidelines.

Send your message to EKG M & E SDN BHD
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

EKG M & E SDN BHD 201201033712 (1018200-D)
27-2 & 27-3, Jalan Kuchai Maju, Kuchai Entrepreneur¡¯s Park, Off Jalan Kuchai Lama, 58200 Kuala Lumpur, Malaysia.

Tel:

Email:
Website: https://www.eakon.com.my
Website: https://eakon.newpages.com.my/
Website: https://eakon.onesync.my/

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

Seni Jaya Logo
Brochure
Download
Our PackageContact Us