Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
Carlssoon Technologies (Malaysia) Sdn Bhd
Carlssoon Technologies (Malaysia) Sdn Bhd 1100021-K
Business
Hours
Monday - Friday 8:30 AM - 5:30 PM
Saturday - Sunday Closed
Open Closed
SSM
601110898891
BryanSoon1009 WeChat QR
WeChat QR

Wechat ID: BryanSoon1009

13-Dec-2020

ANRITSU – Handheld Thermoprinter AP-400 Series
Brand: Anritsu
Model: AP-400 Series
 
Measurement Range:

  • E -200 to 800°C / K -200 to 1370°C
 
Manual print:

  • Manual print-out is available simply by pushing the PRINT key. Measured data with absolute time(Hours:Minutes:Seconds) can be printed.
 
Interval Print:

  • The SET key enables the operator to select a time mode from eight kinds of intervals
 
Number print:

  • The numbering print provides the sequential numbering and measured data.
 
Memory function:

  • The memory function makes it possible to batch print the measured data stored in the internal memory.(max.100 lines data) (Temperature probes not included)
 
Specifications:

Model AP-400 AP-450
Display LCD
Input connector ASP ANP
Channel 1ch
Input (Thermocouple type) Type E or K 
(Not switchable)
Type E, K, J, T, R
(Not switchable)
Signal source resistance Max.500Ω
Measurement range (Table1)
Measurement accuracy (Table2)
Reference junction
compensation accuracy
±0.2°C at 25°C±10°C
Temperature coefficient ±0.01% of measurement range / °C : Outside 25°C±10°C
Environmental limit Operation 0 to 40°C, 0 to 80%RH (Non condensing)
Storage -20 to 50°C, 0 to 85%RH (Non condensing)
Sampling rate (Table3)
Battery life (Table3)
power supply Dry battery 4 AA Alkaline dry cell batteries
AC power AC Adaptor(optional accessories)
Linearizer Digital linearizer method (compliant with IEC 60584-1(2013))
Print out Character size 2.5mm,Paper width 37mm (1000 lines/roll), Thermal line dot printing
Memory 100 data
Internal battery Lithium battery (For clock backup)
Dimensions approx. 68(W)201(H)42(D)mm
[Protruded parts excluded]
Weight approx.350g (include batteries)
Supplied accessories Soft case,4 AA Alkaline dry cell batteries,
Paper jam fixer, User's manual, Print paper(ACAP4),
Test report and User registration form
 
Table 1 Measurement Range

Type °C
1°C Resolution 0.1°C Resolution
E -200 to 800°C -104.9 to 504.9°C
K -200 to 1370°C
J -200 to 1100°C
T -200 to 400°C -104.9 to 400.0°C
R 0 to 1760°C -
* Switches automatically to 1°C resolution range when measured temperatures fall outside the 0.1°C resolution range.
 

Table 2 Measurement Range

Type °C
E, K, J, T 0.1°C Resolution 0°C to ± (0.05% of reading + 0.2°C)
to 0°C ± 0.5°C
1°C Resolution 0°C to ± (0.1% of reading +1°C)
to 0°C ± (0.5% of reading +1°C)
R 1°C Resolution ± (0.1% of reading +3°C)
 
 

Table 3 Sampling rate and Battery life

Interval Sampling rate Battery life
No printing mode 2times / second approx. 110hours
3 seconds 2times / second approx. 15hours
10 seconds 1time / 5seconds approx. 60hours
30 seconds 1time / 5seconds approx. 90hours
1 minute 1time / 10seconds approx. 120hours
5 minutes 1time / minute approx. 8days
10 minutes 1time / minute approx. 9days
30 minutes 1time / minute approx. 10days
60 minutes 1time / minute approx. 10days
 
Optional Accessories:

AC-adaptor AD-100-500-HR-R(for AC100V),AD-115-500-HR-R(for AC115V),
AD-220-500-HR-R(for AC220V)
Print paper ACAP4 (5 pcs/set)

 

Send your message to Carlssoon Technologies (Malaysia) Sdn Bhd
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

Carlssoon Technologies (Malaysia) Sdn Bhd (1100021-K)
No. 54-1, Jalan Niaga Enggang 1, Taman Enggang, 76100 Durian Tunggal, Melaka, Malaysia.

Tel:

Email:
Website: https://www.carlssoon-tech.com
Website: https://carlssoon.newpages.com.my/
Website: https://carlssoon.n.my/

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

  • US 770
  • MY 502
  • CN 369
  • JP 154
  • GB 67
  • NZ 65
  • KR 63
  • CA 59
People Online
Seni Jaya Logo
Brochure
Download
Our PackageContact Us