Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
Hanna Instruments (M) Sdn Bhd
Hanna Instruments (M) Sdn Bhd 198801005697 (173054-W)
Business
Hours
Monday - Friday 8:30 AM - 5:30 PM
Saturday - Sunday Closed
We′re closed on Public Holiday
Open Closed
SSM
VISITORS

Penang,Selangor,Kuala Lumpur (KL),Sabah,Kota Kinabalu,Petaling Jaya,Sungai Nibong - HI8614 pH Transmitter with 4-20 mA Galvanically Isolated Output

30-Jun-2017

The HI8614N and HI8614LN are a water-resistant pH transmitters designed to be used with a standard high impedance pH probe with BNC connector. The signal is then processed by a special high impedance amplifier, which transmits an output current directly proportional to the input signal but independent of changes in load or cable capacitance.

  • Temperature compensation ensures fast, accurately compensated readings even during sudden temperature fluctuations.
  • Water resistant design for use in process control.
  • HI8614LN has optional backlit, LCD display for easy viewing (no LCD on HI8614N)

HI8614 pH Transmitter

 

Two-Wire pH Transmitters

HI 8614 is 2-wire water-resistant transmitter specially designed for long distance measurement of pH in industrial applications.

Two-wire transmitters are widely used for process control in industry. These instruments are particularly useful in industrial conditions where electrical interference is an important factor

By galvanically isolating the signals, any interference created is prevented from reaching the transmitter. Industrial environments are often associated with corrosive conditions, therefore any instrumentation used must be resistant to liquids and corrosion. Hanna transmitters meet all of these criteria and they only use two wires which reduces costs and eliminates the need for an expensive coaxial cable. Two-wire transmitters are ideal when used in remote applications that do not have AC power available.

 

HI8614 pH Transmitter FEATURES/BENEFITS:

Automatic Temperature Compensation (ATC)

  • Temperature compensation is performed by the transmitter’s ATC (Automatic Temperature Compensation) circuitry when measurements are taken with a temperature probe attached; if ATC is not required, it is also possible to substitute a fixed resistor for the temperature probe.

IP Protection

  • The unit is enclosed in a protective casing conforming to IP 65 standards.

Flexible for Your Needs

  • The transmitter can be connected to any Hanna controller that accepts analog input.

Easy Calibration

  • Calibration is performed by the adjustment of two independent trimmers — slope and offset.

BNC Connector

  • The transmitters use a universal BNC socket for quick and secure connection to any electrode with a BNC connector.

Isolated Input

  • The input is isolated from the current loop to eliminate problems related to ground loop, low insulation cables, multiple electrode connections, and a common mode voltage of up to 100V ensures true differential readings

Version with LCD 

  • HI8614”L” versions allow easy verification and monitoring of measured values and is easier to calibrate and maintain.

Easy Installation

  • HI8614 is very easy to install, wall mounted transmitter. It is supplied with 4 mounting screws

SKU HI8614-web
Product Name pH Transmitter with 4-20 mA Galvanically Isolated Output - HI8614
Quote Required Yes
pH Range 0.00 to 14.00 pH; 4–20 mA
pH Resolution (for “L” models) 0.01 pH; 0.01 mA
pH Accuracy ±0.02 pH; ±0.02 mA
pH Calibration offset
pH Temperature Compensation fixed or automatic from 0 to 100°C (32 to 212°F) with HI76608 probe
pH Input impedence 1012 Ohm
Analog Ouput Signal 4-20 mA (isolated)
pH Electrode pH electrode with BNC connector
Display LCD only for HI8614LN
Power Supply HI8614N
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
IP Rating IP65
Dimensions 165 x 110 x 71 mm (6.5 x 4.3 x 2.8’’)
Weight 1 kg (2.2 lb.)
Ordering Information HI8614N and HI8614LN (with display) is supplied with instructions.

Send your message to Hanna Instruments (M) Sdn Bhd
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

Hanna Instruments (M) Sdn Bhd 198801005697 (173054-W)
11A, Jalan PJS 11/20, Bandar Sunway, 46150 Petaling Jaya, Selangor, Malaysia.

Tel:

Email:
Website: https://www.hannamalaysia.com
Website: https://hannamalaysia.newpages.com.my/
Website: https://hannamalaysia.n.my/

Other Office

Hanna Instruments (M) Sdn Bhd (Penang)
N0. 303-2-27, Krystal Point, Jalan Sultan Azlan Shah, 11900 Sungai Nibong, Penang, Malaysia.

Tel:
Fax:
Email:

Hanna Instruments (M) Sdn Bhd (Sabah)
No. 4-1, 1st Floor, Plaza Kingfisher, Jalan Plaza Kingfisher 5, Inanam, 88450 Kota Kinabalu, Sabah, East Malaysia.

Tel:
Fax:
Email:

Hanna Instruments (M) Sdn Bhd (Johor)
No. 49-1, 1st Floor, Jalan Molek 3/10, Taman Molek, 81100 Johor Bahru, Johor, Malaysia.

Tel:
Email:

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

  • US 10770
  • GB 8651
  • CA 7713
  • AU 7335
  • IE 6042
  • NZ 2078
  • BR 1926
  • CN 858
People Online
Seni Jaya Logo
Brochure
Download
Our PackageContact Us