Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
Winston Resources
Winston Resources SA0538712-K
Business
Hours
Monday - Sunday 9:00 AM - 5:00 PM
Open Closed
Onesync Platinum + SSM
VISITORS
Social Media Link
  • wordpress
  • blogger

26-Jul-2016

Features:
‧Constant voltage design
‧Universal AC input / Full range
‧Fully encapsulated with IP67 level(Note.8)
‧Withstand 300VAC surge input for 5 seconds
‧Protections: Short circuit / Overload / Over voltage
‧Fully isolated plastic case
‧Cooling by free air convection
‧100% full load burn-in test
‧Low cost, high reliability
‧Suitable for LED lighting and moving sign applications(Note.7)
‧3 years warranty


Model LPV-100E-5 LPV-100E-12 LPV-100E-15 LPV-100E-24
 
 
Output
DC voltage 5V 12V 15V 24V
Rated current 12A 8.5A        6.7A      4.2A
Current  range 0~12A 0~8.5A 0~6.7A 0~4.2A
Rated  power 60W 102W 100.5W 100.8W
Ripple&noise (max.) 80mVp-p 120mVp-p 120mVp-p  150MVp-p
Voltage tolerance ±8.0% ±5.0%
Line regulation ±1.0%
Load regulation ±6.0% ±2.0%
Setup,rise time 2000ms, 25ms / 230VAC 2000ms, 25ms / 115VAC
Hold up time 50ms/230VAC    14ms/115VAC at  full  load
      Input Voltage range 90 ~ 264VAC 127 ~ 370VDC
Frequency range 47 ~ 63Hz
Efficiency 80% 85% 87% 88%
AC current 2.2A/115VAC 1.2A/230VAC
Inrush current COLD START 75A(twidth=700μs measured at 50% Ipeak) at 230VAC
Leakage current 0.25mA/240VAC
 
Protection
Overload 110 ~ 150% rated output power
Protection type£ºhiccup mode£¬auto-recovery after fault condition is removed
Over voltage 5.75~ 6.75V 13.8~ 16.2V 17.5~ 20.25V 27.6~32.4V
Protection type : Shut off o/p voltage, clamping by zener diode
Environment WORKING TEMP. -25 ~ +70¡æ (Refer to "Derating Curve")
Working humidity 20%~90%RH  non-condensing
Storage temp,humidity -40¡æ~+80¡æ,10%~95%RH
Temp. coefficient ±0.03%/¡æ (0 ~ 50¡æ)
Vibration   10~500HZ,2G 10min/1cycle,period for 60min, each along X, Y, Z axes
 
Safety&EMC
Safety standard         IP67 approved; Design refer to TUV EN60950-1
Withstand voltage I/P-O/P:3KVAC
Isolation resistance I/P-O/P:>100M Ohms / 500VDC / 25¡æ/ 70% RH
EMC emission Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A(≤80% load), EN61000-3-3
EMC immunity Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024, light industry level, criteria A
Others MTBF 703Khrs min. MIL-HDBK-217F (25¡æ)
Dimension 190*52*37mm (L*W*H)
Packing 0.63Kg;20pcs/13.6Kg/0.55CUFT
 
NOTE:
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 ¡æ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by thecomplete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute.
8. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.

Send your message to Winston Resources
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

Winston Resources (SA0538712-K)
Lot 1275, Batu 8, Jalan Bukit Kemuning, Seksyen 32, 40460 Shah Alam, Selangor, Malaysia.

Tel:

Email:
Website: https://www.winstonelectric.com.my
Website: https://winstonelectric.newpages.com.my/
Website: https://winstonelectric.onesync.my/

1
Hello! Thanks for visiting my site. Please press Start button to Contact with Admin :)

Start

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

  • US 1014
  • MY 318
  • CN 127
  • AP 81
  • AU 61
  • SG 33
  • GB 27
  • AR 24
People Online
Seni Jaya Logo
Brochure
Download
Our PackageContact Us