Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
Winston Resources
Winston Resources SA0538712-K
Business
Hours
Monday - Sunday 9:00 AM - 5:00 PM
Open Closed
Onesync Platinum + SSM
VISITORS
Social Media Link
  • wordpress
  • blogger

26-Jul-2016

Features:
·Universal AC input range/Full range
·Built-in active PFC function
·Protections: Short circuit / Over load/Over voltage/Over temperature
·Cooling by free air convection
·Class II power unit
·IP67 design for indoor or outdoor installations
·Suitable for LED lighting and moving sign applications
·Compliance to worldwide safety regulations for lighting
·Suitable for dry / damp / wet locations
·3 years warranty


Model LPF-100-2750 LPF-100-1750 LPF-100-1400
 
 
Output
DC voltage 36V 58V 72V
Constant current region 21.6~36V 34.8~58V 43.2~72V
Rated current 2750mA 1750mA 1400mA
Rated  power 99W 101.5W 100.8W
Ripple&noise (max.) 3.4Vp-p 5.5Vp-p 6.8Vp-p
Voltage tolerance ±5.0%
Current  tolerance ±5.0%
Line  regulation ±3.0%
Load  regulation ±5.0%
Setup time 1200ms/115VAC,500ms/230VAC(Full load)
      Input Voltage range 90¡«264VAC 47¡«63Hz£¬127¡«370VDC
AC current £¨Typ.£© 0.8A/115VAC    0.4A/230VAC
Efficiency 88% 90% 91%
Power factor PF>0.9/230VAC ,PF£¾0.92/115VAC(at full load)
Inrush current Cold start current 40A/230VAC
Leakage current £¼0.75mA/240VAC
 
Protection
Overload 95~110%  rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Over voltage 42~ 46.6V 66~ 78V 82~ 95V
Protection type : Shut down o/p voltage, re-power on to recover
Short circuit Hiccup mode, recovers automatically after fault condition is removed
Over temperature 90¡æ±10¡æ(RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
Environment Working temp, humidity -30¡æ¡«+50¡æ,20%~90%RH  non-condensing
Storage temp,humidity -40¡æ~+80¡æ,10%~95%RH non-condensing
Temp. coefficient ±0.03%/¡æ (0 ~ 50¡æ)
Vibration   10~500HZ,2G 10min/1cycle,period for 60min, X.Y.Z each axes
 
Safety&EMC
Safety standard UL8750, TUV EN61347-1,EN61347-2-13£¬UL60950-1,IP67  Certificated
Withstand voltage I/P-O/P£º3KVAC ,I/P-FG:1.5KVAC,O/P-FG:0.5KVAC 
Isolation resistance I/P-O/P:>100M Ohms / 500VDC / 25¡æ/ 70% RH
EMC interference Compliance to EN55015,EN61000-3-2 Class C(≥65% Load)
EMC emission Compliance to EN61000-3-2  Class C(≥75% Load); EN61000-3-3
EMC immunity Compliance to EN61000-4-2 ,3,4,5,6,8,11; ENV50204,EN55024,EN61547,light industry level (surge 4KV),  criteria B
Others MTBF 420K hrs min. MIL-HDBK-217F (25¡æ)
Dimension 204*49*34mm(L*W*H)
Packing 0.62kg/30pcs/19.5kg/0.027 m³/0.95CUFT
 
NOTE:
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 ¡æ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4.. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design.
5.Derating may be needed under low input voltage. Please check the static characteristics for more details.
6.Setup time is measured at cold start condition. Turning ON/OFF the power supply frequently may  increase  the set up time.
7.The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will
be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

Send your message to Winston Resources
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

Winston Resources (SA0538712-K)
Lot 1275, Batu 8, Jalan Bukit Kemuning, Seksyen 32, 40460 Shah Alam, Selangor, Malaysia.

Tel:

Email:
Website: https://www.winstonelectric.com.my
Website: https://winstonelectric.newpages.com.my/
Website: https://winstonelectric.onesync.my/

1
Hello! Thanks for visiting my site. Please press Start button to Contact with Admin :)

Start

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

  • US 1352
  • MY 996
  • CN 345
  • AP 113
  • KR 48
  • AU 48
  • CA 47
  • IE 40
People Online
Seni Jaya Logo
Brochure
Download
Our PackageContact Us