Redmark Industry Sdn Bhd
Redmark Industry Sdn Bhd 201101007017 (935155-U)
营业
时间
星期一 - 星期日 9:00 AM - 5:00 PM
营业 休息
Onesync AI
访客

19-Mar-2024

Temperature Humidity Test

 

Test Standard: LV124

ü Damp heat, cyclic

Operating mode of DUT

Operating mode II.a

Total test duration

144h

Test variant

Variant 1

Upper test temperature

55 ℃

Number of cycles

6

Number of DUTs

6

 

ü Damp heat, cyclic (with frost)

Operating mode of DUT

Intermitting between 40min operating mode II.a and 10 min operating mode II.c

Total test duration

240h

Number of cycles

10

Test cycle sequence

The first five cycles shall include a cold subcycle and the remaining cycles shall be carried out without a cold subcycle

Number of DUTs

6

 

 

ü Damp heat, steady state

Severity 1

This test shall be carried out in accordance with DIN EN 60068-2-78 with the following parameters.

Operating mode of DUT

Operating mode II.a

Test temperature

40

Humidity

F(rel) = 93%

Test duration

21 dys

Number of DUTs

6

 

Severity 2

This test shall be carried out in accordance with DIN EN 60068-2-78 with the following parameters:

Operating mode of DUT

Intermitting operation between 47h operating mode II.a and

1h operating mode II.c repeating until end of test duration

Test duration

As specifirf in the component requirement specification as per section 12.5.1

Test temperature

65 ℃

Test humidity

93% relative humidity

Number of DUTs

6

 

Prior to the execution of this service life test, a check shall be condected to ascertain whether the high test acceleration using the test parameters 65℃ and 93%RH. Exceeds the physical limits of the materials used in the components (eg. Hydrolysis of plastics). Where applicable, the contractor and client shall agree to changes in the test temperature and test humidity (eg. To +55℃ and 93%RH) while increasing the test duration as per the Lawson model such that the physical limits of the materials used are not exceeded during the test. The overall severity of the testing shall, however, remain unchanged. The test humidity shall not exceed the level of 93% RH.

[Deviating test sequence for components with reduced performance at high temperatures]

For components with reduced performance (e.g. reduction of backlight of LCD displays at high temperatures staring at T (op, max) (65℃) the test shall not - deviating from table 73: Test oarameters K-14 Damp heat, steady state- severity 2 - be carried out at a constant test temperature of 65℃, but with the following parameters (see table 73)

Operating mode of DUT

Intermitting operation as per Figure 33

Test duration

As specified in the component requirement specification as per section 12.5.1 (Lawson model).

The ramp times between 65℃ and T(op,max) shall not be included in the test duration/

Test temperature

The temperature gradient shall be selected such that no condensation occurs at the DUT

Test humidity

93% relative humidity

Interval time T1

47h

Interval time T2

1h

Number of DUTs

6

 


发信息至 Redmark Industry Sdn Bhd
谢谢您的询问!
我们的客服会尽快联络您。
您的名字 *
您的公司名字
您的邮件 *
您的联络号码 *
标题 *
信息 *
验证码 *
总办事处

Redmark Industry Sdn Bhd 201101007017 (935155-U)
38-G, Jalan Setia Utama AU U13/AU, Setia Alam, 40170 Shah Alam, Selangor, Malaysia.

电话:

邮件:
网址: https://www.redmarkindustry.com
网址: https://redmarkindustry.newpages.com.my/
网址: https://redmarkindustry.onesync.my/

其他办事处

Penang Branch
7206, Mez Floor, Kompleks Perniagaan Pangsapuri Seri Cemerlang, Jalan Kampung Paya, Kampung Paya, 12200 Butterworth, Penang, Malaysia.

电话:
手机:
邮件:

Johor Branch
No.93-01, Jalan Molek 1/29, Taman Molek, 81100, Johor Bahru, Johor, Malaysia.

电话:
手机:
邮件:

游览 : 首页 - 分类 - 公司 - 地区 - 标签 - 商品 - 消息与促销 - 工作征聘 - 手机版 - 谷歌 - 搜索引擎优化结果

NEWPAGES

Seni Jaya Logo
Brochure
Download
Our PackageContact Us