Key Features
- Intrinsically Safe with European, USA, Indian and Australian approvals
- Side entry for easy access
- For use with data collector
- Shear Crystal Construction
Industries
Building services, Pulp and Paper, Mining, Metals, Utilities, Automotive, Water, Pharmaceutical
Applications
Fans, Motors, Pumps, Compressors, Centrifuges, Conveyors, Air Handlers, Gearboxes, Rolls, Dryers, Presses, Cooling, VAC, Spindles, Machine Tooling, Process Equipment
| Mounted Base Resonance |
26 – 34 Khz |
|---|---|
| Sensitivity |
±10%, 10mV/g, 30mV/g, 50mV/g, 100mV/g, 250mV/g, 500mV/g, Nominal 80Hz at 22°C / 72°F |
| Operating Temperature Range |
Ex ia I Ma (-55°C ≤ Ta ≤ +103°C) (Mining), Ex ia IIC T4 Ga (-55°C ≤ Ta ≤ +103°C) (Gas, Ex ia IIC T6 Ga (-55°C ≤ Ta ≤ +57°C) (Gas), Ex ia IIIB T110°C Da (-55°C ≤ Ta ≤ +57°C) (Dust), Ex ia IIIB T145°C Da (-55°C ≤ Ta ≤ +92°C) (Dust), Ex ia IIIC T135°C Da (-55°C ≤ Ta ≤ +70°C) (Dust) |
| Sealing |
IP68 |
| EMC |
EN61326-1:2013 |
| Case Material |
Stainless Steel |
| Sensing Element/Construction |
PZT/Shear |
| Weight |
205gms/ 7.2 oz (nominal) body only |
| Screened Cable Assembly |
Silicon – length to be specified with order |
| Top/Side Entry |
Side Entry |
| Feature |
Intrinsically Safe |
| Design |
Premium |
| Connector/Cable Type |
3 Core Silicon Cable with Protective Over-Sheath |
| Output |
Single Output |
| Axis |
Single (Standard) |





BR 18519
VN 12462
US 5301
IN 5129
AR 4281
MY 2408
IQ 2002
CN 1941