Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
EKG M & E SDN BHD
EKG M & E SDN BHD 201201033712 (1018200-D)
Waktu
Pejabat
Isnin - Jumaat 9:00 AM - 5:30 PM
Sabtu 9:00 AM - 1:00 PM
Ahad Closed
We′re closed on Public Holiday
Open Closed
SSM
PENGUNJUNG

24-Mar-2026

Intelligent Rack Cooling Units and Solutions by EKG M&E Sdn Bhd

An Intelligent Rack Cooling Unit (RCU) represents the most granular level of thermal management in a 2026 data centre. Unlike perimeter CRAC units that cool an entire room, an RCU is integrated directly into or onto the server rack. This "close-coupled" approach is essential for high-density AI clusters and GPU farms in Kuala Lumpur, where rack loads often exceed $20\text{kW}$.

EKG M&E Sdn Bhd provides specialized installation and maintenance for RCUs, focusing on micro-climate precision and PUE (Power Usage Effectiveness) reduction.


1. RCU Architectures: Precision at the Source

As an HVAC and Clean Air Specialist, we deploy three primary RCU configurations based on your hardware density:

  • Rear Door Heat Exchangers (RDHx): A chilled water or refrigerant coil is mounted to the back door of the rack. Server fans push hot exhaust through the coil, neutralizing the heat before it enters the room.

  • In-Rack Side-Coolers: Compact cooling loops installed vertically inside the rack frame. These create a closed-loop airflow environment, completely isolating the server from the room's ambient air.

  • Top-of-Rack (ToR) Units: Horizontal cooling modules that pull hot air from the rear plenum and discharge chilled air into the front of the rack.


2. The "Intelligent" Component: VFD & Sensor Fusion

What separates a standard cooler from an Intelligent RCU is its ability to communicate with the server's internal BMC (Baseboard Management Controller). We utilize Variable Frequency Drives (VFDs) to make the cooling truly "dynamic":

Intelligence Feature

Technical Execution

Benefit

Server-Sync Logic

The RCU fan speed tracks the server's CPU utilization.

Eliminates "Over-cooling" and saves up to 40% fan energy.

Pressure Balancing

VFDs maintain neutral pressure at the rack door.

Prevents server fans from "fighting" the cooling unit.

Leak-Guard 360

Integrated moisture sensors and auto-shutoff valves.

Protects sensitive electronics from condensate or coolant leaks.

Real-time PUE

Monitoring of kW used per rack for cooling vs. IT.

Provides granular data for ESG and sustainability reporting.


3. Maintenance and Mechanical Health

Because RCUs are physically attached to IT equipment, maintenance requires surgical precision to prevent mechanical interference:

  • Vibration Spectrum Analysis: We perform FFT analysis on the high-speed RCU fans. If a fan is unbalanced, it can transmit micro-vibrations to the server chassis, potentially causing hard drive (HDD) read/write errors.

  • Coolant Quality Audit: For liquid-based RCUs, we monitor the chemistry of the secondary cooling loop (TCS) to prevent "clogging" of the micro-channels in the heat exchanger.

  • VFD Parameter Tuning: We ensure the VFD ramp-up speeds are optimized to prevent "thermal shock" when an AI model starts training and heat spikes instantly.


4. Why Upgrade to Intelligent RCUs in KL?

In Malaysia’s humid climate, "room-level" cooling is increasingly inefficient for high-performance computing (HPC).

  • Space Optimization: RCUs allow you to pack more servers into a smaller footprint without needing massive "Cold Aisle" containment.

  • Lower PUE: By cooling only the air that needs it, you stop wasting energy on "mixing" and "bypass air."

  • Redundancy (N+1): RCUs can be configured so that if one unit fails, the adjacent units or the perimeter CRAC can provide emergency coverage.


Why Choose EKG M&E Sdn Bhd?

  • 34-Year Legacy: We bridge the gap between heavy mechanical engineering and sensitive IT infrastructure.

  • Turnkey MEP: We manage the Chilled Water Piping, VFD Control Panels, and BMS Software as a single integrated project.

  • Precision Commissioning: We use CFD (Computational Fluid Dynamics) and Thermal Imaging to prove the effectiveness of the RCU before we hand over the site.

Hantar mesej anda ke EKG M & E SDN BHD
Terima kasih untuk pertanyaan anda!
Perkhidmatan pelanggan kami akan menghubungi anda tidak lama lagi.
Nama Anda *
Nama Syarikat Anda
Emel Anda *
Nombor Telefon Anda *
Tajuk *
Mesej *
Captcha *
Pejabat Utama

EKG M & E SDN BHD 201201033712 (1018200-D)
27-2 & 27-3, Jalan Kuchai Maju, Kuchai Entrepreneur¡¯s Park, Off Jalan Kuchai Lama, 58200 Kuala Lumpur, Malaysia.

Tel:

Emel:
Laman Web: https://www.eakon.com.my
Laman Web: https://eakon.newpages.com.my/
Laman Web: https://eakon.onesync.my/

Melayari Melalui : Laman Utama - Klasifikasi - Syarikat - Tempat - Tag - Produk - Berita Baru dan Promosi - Jawatan Kosong - Laman Web Mudah Alih - Google - Keputusan SEO

NEWPAGES

Seni Jaya Logo
Brochure
Download
Our PackageContact Us