Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
Hanna Instruments (M) Sdn Bhd
Hanna Instruments (M) Sdn Bhd 198801005697 (173054-W)
Waktu
Pejabat
Isnin - Jumaat 8:30 AM - 5:30 PM
Sabtu - Ahad Closed
We′re closed on Public Holiday
Open Closed
SSM
PENGUNJUNG

Petaling Jaya - Pengeluar HI510-0320 Universal Controller with Digital Probe Inputs, 3 relays, 2 analog outputs

22-Feb-2023

HI510
Universal Process Controller


HI510 is an advanced universal process controller that can be configured for many applications requiring monitoring and/or control of process parameters. This controller features a digital probe input that will automatically detect and update the meter with the parameter that it measures.
  • Waterproof IP65 (Nema 4X) enclosure
  • Multi-color LED status indicators & audible alarm
  • Universal mounting kits available with wall, pipe, and panel mounting options (All mounting kits must be ordered separately.)
  • The Modbus-compliant unit can be integrated within a Modbus-based network and connected to other industrial electronic devices. The following tasks may be accomplished remotely:
    • Monitoring, using the virtual LCD (limited to a single remote control in the entire network)
    • Setup
    • Loading the Setup configuration file to a controller

 

 
HI510_angleright

Control Modes

Set points for control operations can be configured to be on/off, proportional, or PID types of control. The flexibility in programming allows for fine-tuning of a set point to be maintained with tight control preventing any overshoot and waste of chemicals.

Hold Function

Hold can also be triggered manually and by using and external digital input for disabling control mode when performing maintenance.

Configurable Alarm System

Configurable for set points and temperature or activated by abnormal operation, a red Alarm LED will blink and can easily be seen from a distance. All relays configured for control are inactivated until the alarm state is resolved.

Auto-cleaning cycle

The cleaning function allows the ability to program one or more wash cycles and use the relays to activate valves, pumps or compressed air based on the type of washing that is required to maintain probes for reliable results.
 


HI510_controller_relays

Relays

Available with up to five control and one alarm electromechanical relays.

Analog Outputs

Up to four galvanically isolated analog outputs for control of pumps and valves.

Digital RS485 Output

Can daisy-chain up to 32 devices to a remote monitoring system.

Digital Inputs

Two digital inputs available for modes including disabling, cleaning and placing the controller into hold status.
 


HI510_controller_hold

Large LCD

The LCD displays measurement information along with indicators of potential problems. The DIAG key then provides details of the issue.

HI510_controller_logging

Data-logging

Store info at selectable intervals along with relay control settings and calibrations data.  up to 100 lots, each holding 8600 records. Transfer to a flash drive as a .csv file using the USB Type-C port.

HI510_controller_diagnostic

Help Button

Using the help and diagnostic button (? DIAG) will provide information related to errors or in setup mode, information about settings.
 


SPECIFICATION

Specification Detail
sku HI510
Display Graphic LCD,
128 x 64 pixel B/W with backlight
digital inputs 2 independent,
galvanically isolated inputs,
configurable for Hold & Cleaning functions
On state: 5 to 24 Vdc,
low or high level active
Analog outputs 2 or 4 independent outputs
0 - 22 mA configurable as:
  • 0 - 20mA
  • 4 - 20mA
  • 22 mA as alarm signal
Analog output Accuracy ±0.2% f.s.
Digital Communication
  • RS-485 serial port for remote monitoring and control
  • USB-C port to retrieve log files and firmware upgrades
Relays Up to 5 relays,
independently configurable for process variables,
Hold and CLeaning Functions
Electromechanical relay SPDT and SPST contact outputs
5A - 250 VAC,
5A - 30 Vdc (resistive load)
Fuse protected: 5A,
250V slow blow
Alarm relay for all measurement alarms Electromechanical relay SPDT contact output
5A - 250 Vac,
5A - 30 Vdc (resistive load)
Fuse protected: 5A,
250V slow blow fuse
Data logging
  • Interval log,
    up to 100 files,
    maximum 8600 records on each stored file. When the maximum limit is reached,
    the most recent file with automatically erase the oldest one.
  • Event log,
    maximum 100 records. When the maximum limi
Power Supply 100 - 240 Vac ± 10%,
50/60 Hz,
15VA
Power consumption 15VA
Installation category II
Enclosure* Single case 1/2 DIN,
type 4x IP65 ingress protection
Weight Approximately 1.6 kg,
(3.5 lb.)
Dimensions Width: 144.0 mm (5.7 in.)
Height: 144.0 mm (5.7 in.)
Depth: 151.3 mm (6.0 in.)
Environment -20 to 50°C (-4 to 122°F),
maximum 100% RH non-condensing
Note *For a water tight seal,
tighten the four front casing screws to 13.3 lbf-in (1.5 N-m,
maximum 2.0 N-m) of torque

Hantar mesej anda ke Hanna Instruments (M) Sdn Bhd
Terima kasih untuk pertanyaan anda!
Perkhidmatan pelanggan kami akan menghubungi anda tidak lama lagi.
Nama Anda *
Nama Syarikat Anda
Emel Anda *
Nombor Telefon Anda *
Tajuk *
Mesej *
Captcha *
Pejabat Utama

Hanna Instruments (M) Sdn Bhd 198801005697 (173054-W)
11A, Jalan PJS 11/20, Bandar Sunway, 46150 Petaling Jaya, Selangor, Malaysia.

Tel:

Emel:
Laman Web: https://www.hannamalaysia.com
Laman Web: https://hannamalaysia.newpages.com.my/
Laman Web: https://hannamalaysia.n.my/

Pejabat Lain

Hanna Instruments (M) Sdn Bhd (Penang)
N0. 303-2-27, Krystal Point, Jalan Sultan Azlan Shah, 11900 Sungai Nibong, Penang, Malaysia.

Tel:
Fax:
Emel:

Hanna Instruments (M) Sdn Bhd (Sabah)
No. 4-1, 1st Floor, Plaza Kingfisher, Jalan Plaza Kingfisher 5, Inanam, 88450 Kota Kinabalu, Sabah, East Malaysia.

Tel:
Fax:
Emel:

Hanna Instruments (M) Sdn Bhd (Johor)
No. 49-1, 1st Floor, Jalan Molek 3/10, Taman Molek, 81100 Johor Bahru, Johor, Malaysia.

Tel:
Emel:

Melayari Melalui : Laman Utama - Klasifikasi - Syarikat - Tempat - Tag - Produk - Berita Baru dan Promosi - Jawatan Kosong - Laman Web Mudah Alih - Google - Keputusan SEO

NEWPAGES

  • US 11122
  • GB 8572
  • CA 7983
  • AU 7416
  • IE 5540
  • NZ 2551
  • BR 1694
  • CN 997
Orang dalam talian
Seni Jaya Logo
Brochure
Download
Our PackageContact Us